A SIMPLE, COMPACT SOLUTION FOR CONTROL OF THREE-PHASE CONDENSING UNITS

A SIMPLE, COMPACT SOLUTION FOR CONTROL OF THREE-PHASE CONDENSING UNITS
A SIMPLE, COMPACT SOLUTION FOR CONTROL OF THREE-PHASE CONDENSING UNITS

    A simple, compact solution for control of three-phase condensing units up to 15 HP. The call can be generated by pressure switch (compressor shutdown in pump-down mode), thermostat or clean contact.

    A SIMPLE, COMPACT SOLUTION FOR CONTROL OF THREE-PHASE CONDENSING UNITS
    A SIMPLE, COMPACT SOLUTION FOR CONTROL OF THREE-PHASE CONDENSING UNITS
      Applications
      • Control of condensing unit with three- phase compressor up to 15 HP.

      Main characteristics
      • Direct control of compressor, condenser fans and all standard-compliant electrical safeguards.
      • Compressor call by pressure switch, thermostat or clean contact.
      • Compact unit with self-extinguishing ABS panel and IP65 protection rating plus circuit breaker on front of panel.
      • System status indicated by LED icon.
      Properties
      Dimension
      ECP 15
      350x450x160 mm
      Weight
      ECP 15
      7kg
      Front protection rating
      ECP 15
      IP 65
      Power supply
      ECP 15
      400 VAC ±10% 50/60 Hz
      Status indicator
      ECP 15
      Led
      Load type
      ECP 15
      Three phase
      Working temperature
      ECP 15
      -5 ÷ +50 °C
      Storage temperature
      ECP 15
      -10 ÷ +70°C
      Relative ambient humidity
      ECP 15
      30% - 90% RH without condensate
      Door lock main switch
      ECP 15
      63 A
      Compressor protection
      ECP 15
      Thermal relay
      General protection
      ECP 15
      Fuses
      Control
      ECP 15
      External pressure switch
      Insulation transformer
      ECP 15
      Present
      Pump-down stop
      ECP 15
      Present
      Oil pressure switch
      ECP 15
      Present
      Condenser fans regulator press. switch (r.p.s.)
      ECP 15
      Present
      Thermostat or pressure switch
      ECP 15
      Present
      Kriwan® connection
      ECP 15
      Present
      Compressor
      ECP 15
      7500÷11250W (10÷15 HP)
      Condenser fans output 1
      ECP 15
      2000W(3PH) or 1500W (1PH)
      Condenser fans output 2 (separated)
      ECP 15
      2000W (3PH) or 1500W (1PH)
      Compressor oil heater
      ECP 15
      Present
      Dimension
      ECP 15
      ECP 15
      Connection Scheme
      ECP 15
      ECP 15
      Technical Characteristics
      Inputs
      Outputs
      Dimensions and Diagram
      Available Versions
      ECP 15
      Product Code
      10215B03
      10215B02
      10215B01
      10215B03
      Compressor
      Product Code
      10215B03
      27.0 - 32.0 A
      Product Code
      10215B02
      20.0 - 25.0 A
      Product Code
      10215B01
      14.0 - 20.0 A
      Product Code
      10215B03
      23.0 - 28.0 A
      Compressore Value
      Product Code
      10215B03
      si
      Product Code
      10215B02
      si
      Product Code
      10215B01
      si
      Product Code
      10215B03
      si
      Compressore da
      Product Code
      10215B03
      27.0
      Product Code
      10215B02
      20.0
      Product Code
      10215B01
      14.0
      Product Code
      10215B03
      23.0
      Compressore a
      Product Code
      10215B03
      32.0
      Product Code
      10215B02
      25.0
      Product Code
      10215B01
      20.0
      Product Code
      10215B03
      28.0
      Valvola Evaporatore Value
      Product Code
      10215B03
      no
      Product Code
      10215B02
      no
      Product Code
      10215B01
      no
      Product Code
      10215B03
      no
      Ventola Evaporatore Num
      10215B03
      -
      10215B02
      -
      10215B01
      -
      10215B03
      -
      Evaporator fan
      Product Code
      10215B03
      No
      Product Code
      10215B02
      No
      Product Code
      10215B01
      No
      Product Code
      10215B03
      No
      Defrosting
      Product Code
      10215B03
      No
      Product Code
      10215B02
      No
      Product Code
      10215B01
      No
      Product Code
      10215B03
      No
      Sbrinamento Value
      Product Code
      10215B03
      no
      Product Code
      10215B02
      no
      Product Code
      10215B01
      no
      Product Code
      10215B03
      no
      Sbrinamento Num
      10215B03
      -
      10215B02
      -
      10215B01
      -
      10215B03
      -
      Electronic expansion valve
      Product Code
      10215B03
      No
      Product Code
      10215B02
      No
      Product Code
      10215B01
      No
      Product Code
      10215B03
      No
      Man in cold-room alarm
      Product Code
      10215B03
      No
      Product Code
      10215B02
      No
      Product Code
      10215B01
      No
      Product Code
      10215B03
      No
      Complete cold room management
      Product Code
      10215B03
      No
      Product Code
      10215B02
      No
      Product Code
      10215B01
      No
      Product Code
      10215B03
      No
      Condensing unit management
      Product Code
      10215B03
      Yes
      Product Code
      10215B02
      Yes
      Product Code
      10215B01
      Yes
      Product Code
      10215B03
      Yes
      Temperature/Humidity Management
      Product Code
      10215B03
      No
      Product Code
      10215B02
      No
      Product Code
      10215B01
      No
      Product Code
      10215B03
      No
      Evaporating unit management
      Product Code
      10215B03
      No
      Product Code
      10215B02
      No
      Product Code
      10215B01
      No
      Product Code
      10215B03
      No
      Double system management
      Product Code
      10215B03
      No
      Product Code
      10215B02
      No
      Product Code
      10215B01
      No
      Product Code
      10215B03
      No
      Valve management electronic on/off
      Product Code
      10215B03
      No
      Product Code
      10215B02
      No
      Product Code
      10215B01
      No
      Product Code
      10215B03
      No
      Valve management Stepper electronics
      Product Code
      10215B03
      No
      Product Code
      10215B02
      No
      Product Code
      10215B01
      No
      Product Code
      10215B03
      No
      Double evaporator management
      Product Code
      10215B03
      No
      Product Code
      10215B02
      No
      Product Code
      10215B01
      No
      Product Code
      10215B03
      No
      Datalogger
      Product Code
      10215B03
      No
      Product Code
      10215B02
      No
      Product Code
      10215B01
      No
      Product Code
      10215B03
      No
      Manuals

      Società soggetta all’attività di direzione
      e coordinamento di Castel S.r.l.

      P.I. 01071530297
      Capitale sociale € 100.000,00 i.v.
      Iscrizione Registro Imprese di Rovigo n.01071530297
      REA: 12439

      CONTACT

      Phone: (+39) 0425 762906

      E-Mail: info@pego.it

      Head Office: Via Piacentina, 6/b 45030, Occhiobello (RO)

      Seguici
      sui social

      Copyrights 2024 © Pego | Design and Bulding Teknet.it | Photography ad 3D Models TecnoMedia.biz