PRODUCTS | ELECTRICAL BOARDS
ECP400/750/1000 VD
A LINE OF POWER BOARDS FOR REFRIGERATION SYSTEMS
A line of power boards for refrigeration systems with three-phase compressors up to 10 HP to be linked to a thermostat, thermo-regulator or out-of-room control unit. An electromechanical timer is incorporated for timed defrosts.
Applications
-
Control of three-phase static or ventilated refrigeration units up to 10 HP, with electric or off-cycle defrost linked to a thermostat, thermo-regulator or out-of-room control unit that issues a cold request.
Main characteristics
- Direct control of compressor, condenser fans, compressor oil element, defrost elements, evaporator fans, solenoid valve and all standard-compliant electrical safeguards.
- Compact unit with self-extinguishing ABS housing panel and IP65 protection rating plus circuit breaker on front of panel.
- Electromechanical timer for timed defrosts.
- System status indicated by LED icon.
- Can be controlled by thermostat, thermo-regulator or out-of-room control unit.
- Can house thermo-regulator on front of panel.
Options
- Installation of magnetothermic circuit breakers instead of fuses.
- Compressor shutdown in pump-down mode.
Properties
ECP 400 VD
ECP 750 VD
ECP 1000 VD
Dimension
ECP 400 VD
350x450x160 mm
ECP 750 VD
350x450x160 mm
ECP 1000 VD
350x450x160 mm
Weight
ECP 400 VD
6kg
ECP 750 VD
6kg
ECP 1000 VD
7kg
Front protection rating
ECP 400 VD
IP 65
ECP 750 VD
IP 65
ECP 1000 VD
IP 65
Power supply
ECP 400 VD
400 VAC ±10% 50/60 Hz
ECP 750 VD
400 VAC ±10% 50/60 Hz
ECP 1000 VD
400 VAC ±10% 50/60 Hz
Status indicator
ECP 400 VD
Led
ECP 750 VD
Led
ECP 1000 VD
Led
Load type
ECP 400 VD
Three phase
ECP 750 VD
Three phase
ECP 1000 VD
Three phase
Working temperature
ECP 400 VD
-5 ÷ +50 °C
ECP 750 VD
-5 ÷ +50 °C
ECP 1000 VD
-5 ÷ +50 °C
Storage temperature
ECP 400 VD
-10 ÷ +70°C
ECP 750 VD
-10 ÷ +70°C
ECP 1000 VD
-10 ÷ +70°C
Relative ambient humidity
ECP 400 VD
30% - 90% RH without condensate
ECP 750 VD
30% - 90% RH without condensate
ECP 1000 VD
30% - 90% RH without condensate
Door lock main switch
ECP 400 VD
32 A
ECP 750 VD
32 A
ECP 1000 VD
32 A
Compressor protection
ECP 400 VD
Thermal relay
ECP 750 VD
Thermal relay
ECP 1000 VD
Thermal relay
General protection
ECP 400 VD
Fuses
ECP 750 VD
Fuses
ECP 1000 VD
Fuses
Control
ECP 400 VD
External ON/OFF external thermoregulator - remote control panel
ECP 750 VD
External ON/OFF external thermoregulator - remote control panel
ECP 1000 VD
External ON/OFF external thermoregulator - remote control panel
Alarm signals
ECP 400 VD
Led
ECP 750 VD
Led
ECP 1000 VD
Led
Defrosting
ECP 400 VD
Electrical
ECP 750 VD
Electrical
ECP 1000 VD
Electrical
Insulation transformer
ECP 400 VD
Present
ECP 750 VD
Present
ECP 1000 VD
Present
Oil pressure switch
ECP 400 VD
-
ECP 750 VD
-
ECP 1000 VD
Present
High/low pressure switch
ECP 400 VD
Present
ECP 750 VD
Present
ECP 1000 VD
Present
Condenser fans regulator press. switch (r.p.s.)
ECP 400 VD
Present
ECP 750 VD
Present
ECP 1000 VD
Present
Thermostat or pressure switch
ECP 400 VD
Present
ECP 750 VD
-
ECP 1000 VD
Present
Thermostat or pressure switch
ECP 400 VD
Present
ECP 750 VD
Present
ECP 1000 VD
Present
Kriwan® connection
ECP 400 VD
Present
ECP 750 VD
Present
ECP 1000 VD
Present
Compressor
ECP 400 VD
2200 ÷ 3000W (3÷4 HP)
ECP 750 VD
3000 ÷ 5500W (4÷7,5 HP)
ECP 1000 VD
5500 ÷ 7500W (7÷10 HP)
Defrosting heaters 1
ECP 400 VD
7500W (AC1)
ECP 750 VD
9000W (AC1)
ECP 1000 VD
12000W (AC1)
Evaporator fans 1
ECP 400 VD
1500W (1 PH)
ECP 750 VD
1500W (1 PH)
ECP 1000 VD
2000W (3 PH) or 1500W (1 PH)
Condenser fans output 1
ECP 400 VD
800W totals (1 PH)
ECP 750 VD
800W totals (1 PH)
ECP 1000 VD
2000W(3PH) or 1500W (1PH)
Condenser fans output 2 (separated)
ECP 400 VD
800 W (1PH)
ECP 750 VD
800 W (1PH)
ECP 1000 VD
2000W (3PH) or 1500W (1PH)
Solenoid valve 1
ECP 400 VD
Present
ECP 750 VD
Present
ECP 1000 VD
Present
Compressor oil heater
ECP 400 VD
Present
ECP 750 VD
Present
ECP 1000 VD
Present
Technical Characteristics
Inputs
Outputs
Dimensions and Diagram
Available Versions
ECP 400 VD
ECP 750 VD
ECP 1000 VD
Product Code
102400VD01
102400VD02
102400VD03
Product Code
102750BD02
102750VD01
Product Code
1021000VD02
Compressor
Product Code
102400VD01
102400VD01
5.5 - 8.0 A
Product Code
102400VD02
102400VD02
7.0 - 10.0 A
Product Code
102400VD03
102400VD03
9.0 - 13.0 A
Evaporator fan
Product Code
102400VD01
102400VD01
1,5 kW
Product Code
102400VD02
102400VD02
1,5 kW
Product Code
102400VD03
102400VD03
1,5 kW
Defrosting
Product Code
102400VD01
102400VD01
7,5 kW
Product Code
102400VD02
102400VD02
7,5 kW
Product Code
102400VD03
102400VD03
7,5 kW
Electronic expansion valve
Product Code
102400VD01
102400VD01
No
Product Code
102400VD02
102400VD02
No
Product Code
102400VD03
102400VD03
No
Man in cold-room alarm
Product Code
102400VD01
102400VD01
No
Product Code
102400VD02
102400VD02
No
Product Code
102400VD03
102400VD03
No
Complete cold room management
Product Code
102400VD01
102400VD01
Yes
Product Code
102400VD02
102400VD02
Yes
Product Code
102400VD03
102400VD03
Yes
Condensing unit management
Product Code
102400VD01
102400VD01
No
Product Code
102400VD02
102400VD02
No
Product Code
102400VD03
102400VD03
No
Temperature/Humidity Management
Product Code
102400VD01
102400VD01
No
Product Code
102400VD02
102400VD02
No
Product Code
102400VD03
102400VD03
No
Evaporating unit management
Product Code
102400VD01
102400VD01
No
Product Code
102400VD02
102400VD02
No
Product Code
102400VD03
102400VD03
No
Double system management
Product Code
102400VD01
102400VD01
No
Product Code
102400VD02
102400VD02
No
Product Code
102400VD03
102400VD03
No
Valve management electronic on/off
Product Code
102400VD01
102400VD01
No
Product Code
102400VD02
102400VD02
No
Product Code
102400VD03
102400VD03
No
Valve management Stepper electronics
Product Code
102400VD01
102400VD01
No
Product Code
102400VD02
102400VD02
No
Product Code
102400VD03
102400VD03
No
Double evaporator management
Product Code
102400VD01
102400VD01
No
Product Code
102400VD02
102400VD02
No
Product Code
102400VD03
102400VD03
No
Datalogger
Product Code
102400VD01
102400VD01
No
Product Code
102400VD02
102400VD02
No
Product Code
102400VD03
102400VD03
No
Compressor
Product Code
102750BD02
102750BD02
12.0-18.0 A
Product Code
102750VD01
102750VD01
9.0 - 13.0 A
Evaporator fan
Product Code
102750BD02
102750BD02
1,5 kW
Product Code
102750VD01
102750VD01
1,5 kW
Defrosting
Product Code
102750BD02
102750BD02
9,0 kW
Product Code
102750VD01
102750VD01
9,0 kW
Electronic expansion valve
Product Code
102750BD02
102750BD02
No
Product Code
102750VD01
102750VD01
No
Man in cold-room alarm
Product Code
102750BD02
102750BD02
No
Product Code
102750VD01
102750VD01
No
Complete cold room management
Product Code
102750BD02
102750BD02
Yes
Product Code
102750VD01
102750VD01
Yes
Condensing unit management
Product Code
102750BD02
102750BD02
No
Product Code
102750VD01
102750VD01
No
Temperature/Humidity Management
Product Code
102750BD02
102750BD02
No
Product Code
102750VD01
102750VD01
No
Evaporating unit management
Product Code
102750BD02
102750BD02
No
Product Code
102750VD01
102750VD01
No
Double system management
Product Code
102750BD02
102750BD02
No
Product Code
102750VD01
102750VD01
No
Valve management electronic on/off
Product Code
102750BD02
102750BD02
No
Product Code
102750VD01
102750VD01
No
Valve management Stepper electronics
Product Code
102750BD02
102750BD02
No
Product Code
102750VD01
102750VD01
No
Double evaporator management
Product Code
102750BD02
102750BD02
No
Product Code
102750VD01
102750VD01
No
Datalogger
Product Code
102750BD02
102750BD02
No
Product Code
102750VD01
102750VD01
No
Compressor
Product Code
1021000VD02
1021000VD02
16.0 - 24.0 A
Evaporator fan
Product Code
1021000VD02
1021000VD02
2,0 kW
Defrosting
Product Code
1021000VD02
1021000VD02
12,0 kW
Electronic expansion valve
Product Code
1021000VD02
1021000VD02
No
Man in cold-room alarm
Product Code
1021000VD02
1021000VD02
No
Complete cold room management
Product Code
1021000VD02
1021000VD02
Yes
Condensing unit management
Product Code
1021000VD02
1021000VD02
No
Temperature/Humidity Management
Product Code
1021000VD02
1021000VD02
No
Evaporating unit management
Product Code
1021000VD02
1021000VD02
No
Double system management
Product Code
1021000VD02
1021000VD02
No
Valve management electronic on/off
Product Code
1021000VD02
1021000VD02
No
Valve management Stepper electronics
Product Code
1021000VD02
1021000VD02
No
Double evaporator management
Product Code
1021000VD02
1021000VD02
No
Datalogger
Product Code
1021000VD02
1021000VD02
No
Manuals